VDS Series PC Oscilloscopes User Manual WWW.OWON.COM.HK
Or sometimes it(for Windows 7 x64) may open a window named "Windows Security" as below, and just click "Install" to continue, An
Now the USB driver will work. For Windows XP or Windows 2000 For Windows XP or Windows 2000 Notice: for both x86 and x64. Plug into the running
select [Install from a list or specific location(Advanced)] , select [Search for the best driver in these locations.] , then select [Include this
And complete, And prompt as installed, And show installed in [Device Management], Now you can use the program and use if for USB communicat
II. User Interface 1. Waveform Display Area 2. Display status, click to choose "Disconnect", "Install USB Driver" or "Conne
S: The voltage division of Channel 2 increases one level ←: Time base decreases one level →: Time base increases one level F1: Open this help docu
2.How to Set the Vertical System You can set the corresponding parameters of vertical system in the Channel window (18/19 in II. User Interface).
Note: Different machines have different ranges of time base, here just take VDS3102 for instance. The further from the center, the higher the changin
Choose Mode as "Edge". An edge trigger occurs on trigger threshold value of input signal. Select Edge trigger mode to trigger on rising edge
Instruction of Trigger mode icon in Trigger window: Rise in Edge mode Fall in Edge mode Synchronic trigger in video line Synchronic trigge
Dec. 2013 edition V1.3 Copy Right in this Manual © Lilliput Company. All rights Reserved. The Lilliput's products are under the
Automatic measurement works under this function. Totally twenty kinds of measurements. At most 8 types of measurements could be displayed on the botto
7.How to Implement Sampling Setup Click to show Function menu, choose "Sampling" to set sampling mode. Sampling Mode Description
Click to show Function menu, choose "Mark Cursor". Normal mode 1. Choose source: choose the channel to be measured by cursors betwee
The cursor measurement for FFT mode Check measurement type: choose either Amplitude Measurement or Frequency Measurement at the mode of FFT, or bo
Display Type Click the button to choose the display type (the chosen button has a mark). Vector: The space between the adjacent sampling poin
When the "Infinite" option is set, the measuring points will be stored till the controlling value is changed. Click "Clear" butt
To select the FFT window There are four FFT windows. Each one has trade-offs between frequency resolution and magnitude accuracy. What you want to m
Figure: Rectangle window Figure: Blackman window Figure: Hanning window Notes for u
Main Time Base The setting of the horizontal main time base is used to display the waveform. Assist Set A window area is defined by two cur
12.How to do Pass/Fail test The Pass/Fail function monitors changes of signals and output pass or fail signals by comparing the input signal that i
General Warranty Lilliput warrants that the product will be free from defects in materials and workmanship for a period of 3 years from the date of pu
Save rule Save: Save current rule. Use: Load the selected rule in the list as the testing rule. Remove: Remove the selected rule in the list. 13
1. Choose "Play" tab on the top. 2. Click "From..." to choose the waveform file to be replayed. 3. Set the start frame "Sta&
Click to save screen shot as an image file in png, bmp or gif format. Save/Refer This function allows to store 8 reference waveforms. These wavef
It's a very useful and quick way to apply a set of pre-set functions to the incoming signal, and display the best possible viewing waveform of th
(3) Click "Rework" to restart the oscilloscope. 3. Set the network parameters of the software (1) Supply power: Disconnect the USB cab
2. Set the network parameters of the oscilloscope (1) Connect via USB and enter the menu: Use the supplied USB cable to connect the oscilloscope
(4) Click "Connect". IV. Technical Specifications Unless otherwise specified, the technical specifications applied are for VDS seri
Dual CH 250MS/s Single CH 500GS/s VDS3104 Four CH 250MS/s Dual CH 500MS/s Single CH 1GS/s Input Input coupling DC, AC , Ground Input impedance 1MΩ±2
Scanning speed (S/div) VDS1022(I) VDS2052(I) VDS2062 VDS2064 5ns/div~100s/div, step by 1~2~5 VDS3102 VDS3104 2ns/div~100s/div, step by 1~2~5 Samp
Measurement Cursor △V and △T between cursors Automatic Vpp, Vmax, Vmin, Vtop, Vbase, Vamp, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, F
Table of Contents Table of Contents ...
Performance Characteristics Instruction Time setting VDS1022(I) VDS2052(I) VDS2062 VDS3102 VDS2064 VDS3104 30ns~10s Alternate Trigger Trigger on CH
VDS Oscilloscope Software Help Welcome to VDS Oscilloscope software. The supplied accessories of the oscilloscope include a Quick Guide. The Quick
VDS2062/VDS3102 5674 Figure: Ports of the Oscilloscope (take VDS3102 for instance) 1. RS-232C Port (optional) 2. USB port: Supply power by PC USB
I. PC Software USB Driver Install Guide Use the supplied USB cable to connect the oscilloscope with a PC through their USB ports. Note: If you use
The next window, select a directory path for the driver software location, and click "Next", Notice: the driver software location is a di
OK, back to the driver installing, after last "Next" step, the system is installing driver software for you, as follow, In the course,